Design Values:

 Attribute Value
 Layup Combination 24F-V4
 Flexural Stress Fb (psi)2
 Tension Zone
2,400
 Flexural Stress Fb (psi)2 -
 Compression Zone
1,850
 Compression Perpendicular
 to Grain Fc1 (psi)
650
 Shear Fv (psi)3 265
 MOE (106 psi) - Apparent 1.8
 MOE (106 psi) - True 1.9


Notes:

  1. Fb shall be adjusted by the volume effect factor using the following formula: Cv = (5.125/b)1/10 x (12/d)1/10 x (21/L) 1/10 < 1.0 where: b = beam width (in), d = beam depth (in), L = beam length (ft)
  2. For non-prismatic members, notched members, members subject to impact or cyclic loading, or shear design of bending members at connections (NDS-05 3.4.3.3), the design shear (Fv) shall be multiplied by a factor of 0.72.
  3. The Fv values do not include adjustments for checking.

Sizes:I-Joist Dept X-Beam

  • Inventoried Widths: 3-1/2", 5-1/2" 6-3/4", 8-3/4"
  • Inventoried Depths
    • Conventional depths 6" to 24" in 1-1/2" increments
    • (IJC) I-Joist compatible depths 9-1/2", 11-7/8", 14", 16", 18"
    • X-Beam also available in 9-1/4” and 11-1/4” depths to match 2x10 and 2x12

X-Beam Columns

X-Beam glulam columns are architectural appearance, surfaced four sides and all four edges are eased. These glulam columns remain straight and true.

  • Column Sizes: 3-1/2" x 6", 5-1/2" x 5-1/2", 5-1/2" x 6"